current location: Home >> Products >> Motor maintenance
Burned part
Burned part

Burned part

  • Category:Motor maintenance
  • Date:2023-10-20
Consultation hotline:15806202008
  • summary

Reason for motor burning

1. Excessive load

For example, in a one bag noodle washing machine, some users insist on washing one and a half bags, or even two bags of noodles. This is a typical small horse pulling a cart, and over time, the horse becomes exhausted.

2. Overheating

Using under high temperature conditions, or in particularly poorly ventilated areas, or even near furnaces, is also a major factor in causing motor damage.

3. Dampness

Most of the current motors have moisture-proof treatment, but if you accidentally spill water frequently, please cut off the power immediately and use it after drying with a fan. Otherwise, it will burn out the motor.

4. Hard start

Our machines can all rotate in both forward and reverse directions. When switching the direction of rotation, it is important to wait for the previous direction to stop before switching, otherwise the motor may burn out.

5. Voltage instability

The main manifestation is the looseness of the wiring, which makes it easy for the terminal to ignite, causing voltage fluctuations and fatal damage to the motor. Therefore, we solemnly declare that none of our machines are equipped with plugs, and it is necessary to directly connect the motor to the leakage protector. It is strictly prohibited to connect plugs without authorization, which may cause safety hazards.

6. Low voltage

Low voltage is mainly caused by two factors. One reason is that the power cord is too thin. We have compiled a table of power cord thickness and power, please click to view it. The second issue is that the power cord is too long. Remember: For high-power appliances, the shorter the power cord, the better. That's why many large manufacturers provide machines with very short lengths of wire. It's not because big manufacturers are stingy, but because big manufacturers are more considerate.

7. Phase deficiency

80% of the three-phase electric motor burnout is related to phase loss. So, after wiring, it is necessary to ensure that the three live wires connected to the motor are connected. If you don't know how to wire, you can contact us or find a professional electrician to wire.


label

Recently browsed:

Related products

Related News

Contact

Contact person: Wang Yun

mobile phone:15806202008

phone:0512-62752166

Fax:0512-62753166

Email:yun.wang@ruisiman.com.cn

Website:www.ruisiman.com.cn

Address: 9th Floor, Zhongqi Zero Building, Aigehao Road, Xiangcheng District, Suzhou City


Copyright © Jiangsu Ruisman Energy Saving Technology Co., Ltd All rights reserved Filing number:苏ICP备16056353号 Specializing in ,Welcome to inquire!   苏ICP备16056353号 Technical Support:创企云